AMENDMENT 01:
The purpose of this amendment is to:
Notify interested vendors that the question and answering period for the solicitation is now closed.
Incorporate the mechanical drawings as a standalone attachment, designated as Atch-03 (Bldg 503 Floor Plan - Mechanical Specs).
Incorporate Atch 04, Questions and Answers.
Extend the solicitation close date to Tuesday, 11 Aug 2026 at 4:00 PM EDT as a result of this amendment.
Note: The conformed copy of the origianl solcitation and the amendment is incorported into the attachments as "Solicitation Amendment - FA441826Q00800001". The standalone amendment is incorporated in the attachments as "Solicitation Amendment FA441826Q00800001 SF 30".
The Department of the Air Force, Joint Base Charleston, is issuing this Request for Quote (RFQ) to procure HVAC Duct Cleaning Services for Bldg. 503 in accordance with the attached Statement of Work (see Atch-01).
Please refer to FAR 52.212-1 and FAR 52.212-2 within the attached SF 1449 for complete submission instructions and the specific evaluation criteria that will be used to determine the best value to the Government.
The work involves cleaning HVAC ductwork and components at Bldg. 503, Joint Base Charleston, SC, including 4 VAV Air Conditioner Units, 3 Exhaust Fans (EF-1, EF-2, EF-3), 24 Fan Powered Boxes, 26 VAV Boxes, and all supply and return air diffusers, registers, and grilles. The contractor must perform source removal and disposal of contaminants, use HEPA-filtered vacuum equipment, compressed air, agitation devices, and negative air machines, and clean all interior surfaces of exhaust fans, fan powered boxes, VAV boxes, and air devices. Work must comply with NADCA and IICRC standards. The contractor must provide a post-project documentation report with before-and-after photographs, a signed statement certifying NADCA compliance, and proof of proper waste disposal.
"29404-5021""JOINT BASE CHARLESTON""SC""USA""CP 843 963 5155""101 E HILL BLVD""Solicitation Amendment FA441826Q00800001 SF 30.pdf"463416"file"".pdf""1""2026-08-06T22:40:20.288+00:00""51a08d1202064195941001ebc45ff322""public""0""public""ef0548dad8354bd1bcea4c7c346f227c""0"18"0""Solicitation Amendment - FA441826Q00800001.pdf"558940"file"".pdf""1""2026-08-06T22:40:20.288+00:00""67ac69adbb244d17872783da5fec5bff""public""0""public""a46630f5f2cf40c0b97f996b356c7132""0"17"0""Solicitation - FA441826Q0080.pdf"556561"file"".pdf""1""2026-08-03T16:00:49.149+00:00""98d6c652ff604d68966c63a629f1a123""public""0""public""c96b258b6117404a98d5019da48bca83""0"15"0""Atch-01 Bldg 503 HVAC Duct Cleaning Statement of Work.pdf"4654021"file"".pdf""1""2026-08-03T16:00:49.149+00:00""6768084386a54bd8b6d53cd9beecc6cf""public""0""public""6fbf5a6d97a6432f906482472a4b82eb""0"12"0""Atch-02 SCA WD 2015-4427 rev 33_20260513.pdf"257327"file"".pdf""1""2026-08-03T16:00:49.149+00:00""a8b1c756d7f342b4a959973f7f44db8e""public""0""public""65c7651d59ce4e67981171d371eecbf6""0"8"0""Atch-03 Bldg 503 Floor Plan - Mechanical Specs.pdf"4911774"file"".pdf""1""2026-08-06T22:40:20.288+00:00""23d5cb8957c742999cda31b6406f150d""public""0""public""e0c2bab812c846f990aae7b157910430""0"6"0""Atch 04 FA441826Q0080 Questions and Answers.pdf"158511"file"".pdf""1""2026-08-06T22:40:20.288+00:00""fe47bff6c3e3499197ff4f95c66f43a5""public""0""public""c2e416f5971f4fd198f294596cd68651""0"5"0"Source: SAM.gov (notice d11fb4c19e914e5999ea7415be2d85b1), retrieved via the SAM.gov Get Opportunities API. View the official posting , always confirm requirements and deadlines with the issuing agency.