We post new equipment maintenance & rental opportunities in Virginia as agencies publish them. Get them in one email — free, and unsubscribe whenever.
IFB for Powhatan Maintenance and Repair 2026
The contractor will perform maintenance and repair on the MV Powhatan, including work on the side shell and longitudinal elevations, superstructure scantlings, deck and bottom structure, docking plan and cathodic protection, fuel oil system, fixed fire extinguishing system, engine room ventilation fans, fresh and sanitary water plumbing, firemain system, engine cooling system, bilge and waste oil system, compressed air system, and seachest. The work also involves CAT start air piping, CO2 hydro testing, keel cooler layout, grid cooler installation, Voith health check and cooling system repairs, non-skid application, and compliance with marine paint standards and federal aid construction contracts.
["https://procure.cgieva.com/page.aspx/en/fil/download_public/CB6F04DB-51BC-45B4-A37B-B2256D61310B","https://procure.cgieva.com/page.aspx/en/fil/download_public/35A8893E-2707-4615-AE10-156B454030C4","https://procure.cgieva.com/page.aspx/en/fil/download_public/F31C9BA6-E226-4E3C-AD2C-CB62ACCBAB0F","https://procure.cgieva.com/page.aspx/en/fil/download_public/27A0F776-93D2-400B-8E5E-EAA39FB2D7AF","https://procure.cgieva.com/page.aspx/en/fil/download_public/F96936D8-30A2-4F02-9F3F-591DE433C855","https://procure.cgieva.com/page.aspx/en/fil/download_public/4AE71C61-48FA-4BA4-8113-04832607AEE2","https://procure.cgieva.com/page.aspx/en/fil/download_public/2D9116E1-E8CD-4A0B-8521-831F7B4EA120","https://procure.cgieva.com/page.aspx/en/fil/download_public/D7733C29-FFC0-42F8-8E11-4AC694560962","https://procure.cgieva.com/page.aspx/en/fil/download_public/3A90AD85-6AC2-44D2-B72C-CCE74E176C49","https://procure.cgieva.com/page.aspx/en/fil/download_public/D839C2B8-B39C-462A-9160-A970F63745DB","https://procure.cgieva.com/page.aspx/en/fil/download_public/B018F1B2-F474-44C9-BCD4-8FC554761112","https://procure.cgieva.com/page.aspx/en/fil/download_public/60855E8F-0BFF-4D7B-A383-14B2BD06AEDA","https://procure.cgieva.com/page.aspx/en/fil/download_public/A6253FF1-CC2E-4C8A-8F33-1AED57F19A64","https://procure.cgieva.com/page.aspx/en/fil/download_public/CF7124D0-8C8B-409D-8636-8040A4D6EF4F","https://procure.cgieva.com/page.aspx/en/fil/download_public/CCC7F78C-6D86-4C66-87E2-2F3F064AE97A","https://procure.cgieva.com/page.aspx/en/fil/download_public/37907EE1-707C-4D79-838E-DFC067AEB7EE","https://procure.cgieva.com/page.aspx/en/fil/download_public/46A85B8C-30A2-491D-B647-21D9D21B6B8A","https://procure.cgieva.com/page.aspx/en/fil/download_public/47BB9144-8C23-4742-8F82-F7F983D1E7A1","https://procure.cgieva.com/page.aspx/en/fil/download_public/144E80FD-5272-4E6B-9B81-58CD959FD70A","https://procure.cgieva.com/page.aspx/en/fil/download_public/8923428D-E65A-4F73-9871-06A183FF54D2","https://procure.cgieva.com/page.aspx/en/fil/download_public/E7A54C2A-EF49-4A1C-A20C-107C143BC731","https://procure.cgieva.com/page.aspx/en/fil/download_public/FCEC7BB7-4793-41C8-91BA-FF334273ACEF","https://procure.cgieva.com/page.aspx/en/fil/download_public/514EC8DA-C387-4902-9FA0-A113100A0C66","https://procure.cgieva.com/page.aspx/en/fil/download_public/2B20DE60-9AB9-4972-BBFD-6266CB0D557D","https://procure.cgieva.com/page.aspx/en/fil/download_public/BFC94887-C7F3-4312-903A-1AABE88ABE1F","https://procure.cgieva.com/page.aspx/en/fil/download_public/310C4DF9-BF5E-44DC-9A28-C5AFD17DEB2B","https://procure.cgieva.com/page.aspx/en/fil/download_public/2963A3A4-6395-4569-B255-271707843463","https://procure.cgieva.com/page.aspx/en/fil/download_public/9ACC8DF3-1E21-4AD5-B2D8-1C4C6F38BA62","https://procure.cgieva.com/page.aspx/en/fil/download_public/711CAED5-CD05-411C-B2FC-DD3B4126F6DA","https://procure.cgieva.com/page.aspx/en/fil/download_public/5B518893-293A-4B9C-BC41-B1AB0E141AB8","https://procure.cgieva.com/page.aspx/en/fil/download_public/C8730CED-30C9-4532-A10F-25C0A4716EC1","https://procure.cgieva.com/page.aspx/en/fil/download_public/65872023-D65F-492F-BBDE-C3B8C0059135","https://procure.cgieva.com/page.aspx/en/fil/download_public/749E8D25-4B35-4A7F-AD87-AADF95FEE4E3","https://procure.cgieva.com/page.aspx/en/fil/download_public/9461D8D9-3FD7-4851-83F2-E700B7E26290","https://procure.cgieva.com/page.aspx/en/fil/download_public/4484756E-0500-440B-A8A5-FCD310AC1D39","https://procure.cgieva.com/page.aspx/en/fil/download_public/0F3F05AE-46A3-4467-A1BA-61D6254262C4","https://procure.cgieva.com/page.aspx/en/fil/download_public/AD5B22E5-2366-4831-8585-0CA5E0AB63B3","https://procure.cgieva.com/page.aspx/en/fil/download_public/E5F97696-EF9E-445F-9F8E-F0BF78B72758","https://procure.cgieva.com/page.aspx/en/fil/download_public/96245BDC-D9A9-480D-A66A-E1F7D7BB7CAC","https://procure.cgieva.com/page.aspx/en/fil/download_public/AB08749D-9DAB-4050-884B-B7F475802A0B","https://procure.cgieva.com/page.aspx/en/fil/download_public/534FB594-8BD5-4C6F-A036-D1AD3A02ED86","https://procure.cgieva.com/page.aspx/en/fil/download_public/20C714B4-F30A-4CFC-9E31-1895EA5FEACA","https://procure.cgieva.com/page.aspx/en/fil/download_public/4FC7AAA9-9B8B-4517-8A1C-4D64B36D4045","https://procure.cgieva.com/page.aspx/en/fil/download_public/C665D44F-66CD-41DD-8E3A-12EDBFC758B4","https://procure.cgieva.com/page.aspx/en/fil/download_public/F1A9D860-7964-4513-96C7-933D59D3138A","https://procure.cgieva.com/page.aspx/en/fil/download_public/999F3F13-16D2-4C04-8518-A2D8DE81F0DE","https://procure.cgieva.com/page.aspx/en/fil/download_public/68A996A9-6060-41A8-9665-193EBFAA6665"]["<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/CB6F04DB-51BC-45B4-A37B-B2256D61310B\"\">161025 Attachment K - POWHATAN SIDE SHELL & LONGITUDINAL ELEVATIONS.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/35A8893E-2707-4615-AE10-156B454030C4\"\">161025 Attachment UU - Powhatan B CAT start air piping (1).JPG</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/F31C9BA6-E226-4E3C-AD2C-CB62ACCBAB0F\"\">161025 Attachment AA - Powhatan A CAT start air piping (1).JPG</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/27A0F776-93D2-400B-8E5E-EAA39FB2D7AF\"\">161025 Attachment BB - Powhatan A CAT start air piping (2).jpg</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/F96936D8-30A2-4F02-9F3F-591DE433C855\"\">161025 Attachment CC - Powhatan A CAT start air piping (3).JPG</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/4AE71C61-48FA-4BA4-8113-04832607AEE2\"\">161025 Attachment DD - Powhatan - CO2 Hydro Test Dates.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/2D9116E1-E8CD-4A0B-8521-831F7B4EA120\"\">161025 Attachment EE - MSC.1-Circ.1318-Rev.1.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/D7733C29-FFC0-42F8-8E11-4AC694560962\"\">161025 Attachment F - Federal Aid Construction Contracts FHWA-1273.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/3A90AD85-6AC2-44D2-B72C-CCE74E176C49\"\">161025 Attachment FF - Manchester Air Receiver ID 1 (Picture).jpg</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/D839C2B8-B39C-462A-9160-A970F63745DB\"\">161025 Attachment G Specifications for the Maintenance and Repair MV Powhatan.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/B018F1B2-F474-44C9-BCD4-8FC554761112\"\">161025 Attachment GG - Manchester Air Receiver ID 2 (Picture).jpg</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/60855E8F-0BFF-4D7B-A383-14B2BD06AEDA\"\">161025 Attachment H - 33 CFR 105 Marine Transportation Security Act.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/A6253FF1-CC2E-4C8A-8F33-1AED57F19A64\"\">161025 Attachment HH - Form C-76A Contractors Certificate Compliance for Construction Materials.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/CF7124D0-8C8B-409D-8636-8040A4D6EF4F\"\">161025 Attachment I - 46CFR Part 1520.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/CCC7F78C-6D86-4C66-87E2-2F3F064AE97A\"\">161025 Attachment J - POWHATAN SUPERSTRUCTURE SCANTLINGS.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/37907EE1-707C-4D79-838E-DFC067AEB7EE\"\">161025 Attachment KK - Fernstrum Grid Cooler Installation and Maintenance Manual.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/46A85B8C-30A2-491D-B647-21D9D21B6B8A\"\">161025 Attachment L - Powhatan Red Fox Installation Operation Maintenance Manual.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/47BB9144-8C23-4742-8F82-F7F983D1E7A1\"\">161025 Attachment LL - CG-ENG PL 02-23_Acceptance of IMO Hydrostatic Guidelines_1.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/144E80FD-5272-4E6B-9B81-58CD959FD70A\"\">161025 Attachment M - Powhatan keel cooler layout with notes.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/8923428D-E65A-4F73-9871-06A183FF54D2\"\">161025 Attachment MM-CFR 147.65 Carbon Dioxide and Halon Fire Extinguishing Systems.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/E7A54C2A-EF49-4A1C-A20C-107C143BC731\"\">161025 Attachment N- POWHATAN GENERAL ARRANGEMENT.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/FCEC7BB7-4793-41C8-91BA-FF334273ACEF\"\">161025 Attachment NN - 5.07.2.4. Non-Skid Estimated Square Footage Per Space.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/514EC8DA-C387-4902-9FA0-A113100A0C66\"\">161025 Attachment O - POWHATAN FUEL OIL SYSTEM DIAGRAM.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/2B20DE60-9AB9-4972-BBFD-6266CB0D557D\"\">161025 Attachment OO - Voith Health Check Brochure.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/BFC94887-C7F3-4312-903A-1AABE88ABE1F\"\">161025 Attachment P - POWHATAN FIXED FIRE EXTINGUISHING SYSTEM DIAGRAM.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/310C4DF9-BF5E-44DC-9A28-C5AFD17DEB2B\"\">161025 Attachment PP - Voith expansion tank modification.jpg</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/2963A3A4-6395-4569-B255-271707843463\"\">161025 Attachment Q - POWHATAN ER VENTILATION FAN (1).pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/9ACC8DF3-1E21-4AD5-B2D8-1C4C6F38BA62\"\">161025 Attachment QQ- Voith cooling system leaking pipe.JPG</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/711CAED5-CD05-411C-B2FC-DD3B4126F6DA\"\">161025 Attachment R - POWHATAN ER VENTILATION FAN (2).pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/5B518893-293A-4B9C-BC41-B1AB0E141AB8\"\">161025 Attachment RR - VDOT Special Provision SP107-003000-01.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/C8730CED-30C9-4532-A10F-25C0A4716EC1\"\">161025 Attachment S - POWHATAN DOCKING PLAN & CATHODIC PROTECTION.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/65872023-D65F-492F-BBDE-C3B8C0059135\"\">161025 Attachment SS - VDOT Marine Paint Standards for Preservation.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/749E8D25-4B35-4A7F-AD87-AADF95FEE4E3\"\">161025 Attachment T - POWHATAN DECK & BOTTOM STRUCTURE.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/9461D8D9-3FD7-4851-83F2-E700B7E26290\"\">161025 Attachment TT- Tsurumi Submersible Effluent Pump.JPG</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/4484756E-0500-440B-A8A5-FCD310AC1D39\"\">161025 Attachment U - POWHATAN AS-BUILT SEACHEST.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/0F3F05AE-46A3-4467-A1BA-61D6254262C4\"\">161025 Attachment V - POWHATAN AS-BUILT FRESH & SANITARY WATER PLMB & DE DRN.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/AD5B22E5-2366-4831-8585-0CA5E0AB63B3\"\">161025 Attachment VV - Powhatan B CAT start air piping (2).JPG</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/E5F97696-EF9E-445F-9F8E-F0BF78B72758\"\">161025 Attachment W - POWHATAN AS-BUILT FIREMAIN SYSTEM DIAGRAM.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/96245BDC-D9A9-480D-A66A-E1F7D7BB7CAC\"\">161025 Attachment WW - Powhatan B CAT start air piping (3).JPG</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/AB08749D-9DAB-4050-884B-B7F475802A0B\"\">161025 Attachment X - POWHATAN AS-BUILT ENGINE COOLING SYSTEM DIAGRAM.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/534FB594-8BD5-4C6F-A036-D1AD3A02ED86\"\">161025 Attachment XX - POWHATAN OUTBOARD PROFILE LIFE JACKET STORAGE.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/20C714B4-F30A-4CFC-9E31-1895EA5FEACA\"\">161025 Attachment Y - POWHATAN AS-BUILT BILGE AND WASTE OIL SYSTEM.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/4FC7AAA9-9B8B-4517-8A1C-4D64B36D4045\"\">161025 Attachment Z - POWHATAN AS BUILT COMPRESSED AIR SYSTEM DIAGRAM.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/C665D44F-66CD-41DD-8E3A-12EDBFC758B4\"\">161025 Attachments A-E.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/F1A9D860-7964-4513-96C7-933D59D3138A\"\">161025 II - Form C-76B - CONTRACTOR’S CERTIFICATE OF COMPLIANCE FOR MANUFACTURED PRODUCTS.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/999F3F13-16D2-4C04-8518-A2D8DE81F0DE\"\">161025 JJ Form C-76 - CONTRACTOR’S CERTIFICATE OF COMPLIANCE FOR STEEL & IRON ITEMS.pdf</a>","<a href=\"\"https://procure.cgieva.com/page.aspx/en/fil/download_public/68A996A9-6060-41A8-9665-193EBFAA6665\"\">IFB 161025 Powhatan Shipyard- Solicitation.pdf</a>"]["CB6F04DB-51BC-45B4-A37B-B2256D61310B","35A8893E-2707-4615-AE10-156B454030C4","F31C9BA6-E226-4E3C-AD2C-CB62ACCBAB0F","27A0F776-93D2-400B-8E5E-EAA39FB2D7AF","F96936D8-30A2-4F02-9F3F-591DE433C855","4AE71C61-48FA-4BA4-8113-04832607AEE2","2D9116E1-E8CD-4A0B-8521-831F7B4EA120","D7733C29-FFC0-42F8-8E11-4AC694560962","3A90AD85-6AC2-44D2-B72C-CCE74E176C49","D839C2B8-B39C-462A-9160-A970F63745DB","B018F1B2-F474-44C9-BCD4-8FC554761112","60855E8F-0BFF-4D7B-A383-14B2BD06AEDA","A6253FF1-CC2E-4C8A-8F33-1AED57F19A64","CF7124D0-8C8B-409D-8636-8040A4D6EF4F","CCC7F78C-6D86-4C66-87E2-2F3F064AE97A","37907EE1-707C-4D79-838E-DFC067AEB7EE","46A85B8C-30A2-491D-B647-21D9D21B6B8A","47BB9144-8C23-4742-8F82-F7F983D1E7A1","144E80FD-5272-4E6B-9B81-58CD959FD70A","8923428D-E65A-4F73-9871-06A183FF54D2","E7A54C2A-EF49-4A1C-A20C-107C143BC731","FCEC7BB7-4793-41C8-91BA-FF334273ACEF","514EC8DA-C387-4902-9FA0-A113100A0C66","2B20DE60-9AB9-4972-BBFD-6266CB0D557D","BFC94887-C7F3-4312-903A-1AABE88ABE1F","310C4DF9-BF5E-44DC-9A28-C5AFD17DEB2B","2963A3A4-6395-4569-B255-271707843463","9ACC8DF3-1E21-4AD5-B2D8-1C4C6F38BA62","711CAED5-CD05-411C-B2FC-DD3B4126F6DA","5B518893-293A-4B9C-BC41-B1AB0E141AB8","C8730CED-30C9-4532-A10F-25C0A4716EC1","65872023-D65F-492F-BBDE-C3B8C0059135","749E8D25-4B35-4A7F-AD87-AADF95FEE4E3","9461D8D9-3FD7-4851-83F2-E700B7E26290","4484756E-0500-440B-A8A5-FCD310AC1D39","0F3F05AE-46A3-4467-A1BA-61D6254262C4","AD5B22E5-2366-4831-8585-0CA5E0AB63B3","E5F97696-EF9E-445F-9F8E-F0BF78B72758","96245BDC-D9A9-480D-A66A-E1F7D7BB7CAC","AB08749D-9DAB-4050-884B-B7F475802A0B","534FB594-8BD5-4C6F-A036-D1AD3A02ED86","20C714B4-F30A-4CFC-9E31-1895EA5FEACA","4FC7AAA9-9B8B-4517-8A1C-4D64B36D4045","C665D44F-66CD-41DD-8E3A-12EDBFC758B4","F1A9D860-7964-4513-96C7-933D59D3138A","999F3F13-16D2-4C04-8518-A2D8DE81F0DE","68A996A9-6060-41A8-9665-193EBFAA6665"]["161025 Attachment K - POWHATAN SIDE SHELL & LONGITUDINAL ELEVATIONS.pdf","161025 Attachment UU - Powhatan B CAT start air piping (1).JPG","161025 Attachment AA - Powhatan A CAT start air piping (1).JPG","161025 Attachment BB - Powhatan A CAT start air piping (2).jpg","161025 Attachment CC - Powhatan A CAT start air piping (3).JPG","161025 Attachment DD - Powhatan - CO2 Hydro Test Dates.pdf","161025 Attachment EE - MSC.1-Circ.1318-Rev.1.pdf","161025 Attachment F - Federal Aid Construction Contracts FHWA-1273.pdf","161025 Attachment FF - Manchester Air Receiver ID 1 (Picture).jpg","161025 Attachment G Specifications for the Maintenance and Repair MV Powhatan.pdf","161025 Attachment GG - Manchester Air Receiver ID 2 (Picture).jpg","161025 Attachment H - 33 CFR 105 Marine Transportation Security Act.pdf","161025 Attachment HH - Form C-76A Contractors Certificate Compliance for Construction Materials.pdf","161025 Attachment I - 46CFR Part 1520.pdf","161025 Attachment J - POWHATAN SUPERSTRUCTURE SCANTLINGS.pdf","161025 Attachment KK - Fernstrum Grid Cooler Installation and Maintenance Manual.pdf","161025 Attachment L - Powhatan Red Fox Installation Operation Maintenance Manual.pdf","161025 Attachment LL - CG-ENG PL 02-23_Acceptance of IMO Hydrostatic Guidelines_1.pdf","161025 Attachment M - Powhatan keel cooler layout with notes.pdf","161025 Attachment MM-CFR 147.65 Carbon Dioxide and Halon Fire Extinguishing Systems.pdf","161025 Attachment N- POWHATAN GENERAL ARRANGEMENT.pdf","161025 Attachment NN - 5.07.2.4. Non-Skid Estimated Square Footage Per Space.pdf","161025 Attachment O - POWHATAN FUEL OIL SYSTEM DIAGRAM.pdf","161025 Attachment OO - Voith Health Check Brochure.pdf","161025 Attachment P - POWHATAN FIXED FIRE EXTINGUISHING SYSTEM DIAGRAM.pdf","161025 Attachment PP - Voith expansion tank modification.jpg","161025 Attachment Q - POWHATAN ER VENTILATION FAN (1).pdf","161025 Attachment QQ- Voith cooling system leaking pipe.JPG","161025 Attachment R - POWHATAN ER VENTILATION FAN (2).pdf","161025 Attachment RR - VDOT Special Provision SP107-003000-01.pdf","161025 Attachment S - POWHATAN DOCKING PLAN & CATHODIC PROTECTION.pdf","161025 Attachment SS - VDOT Marine Paint Standards for Preservation.pdf","161025 Attachment T - POWHATAN DECK & BOTTOM STRUCTURE.pdf","161025 Attachment TT- Tsurumi Submersible Effluent Pump.JPG","161025 Attachment U - POWHATAN AS-BUILT SEACHEST.pdf","161025 Attachment V - POWHATAN AS-BUILT FRESH & SANITARY WATER PLMB & DE DRN.pdf","161025 Attachment VV - Powhatan B CAT start air piping (2).JPG","161025 Attachment W - POWHATAN AS-BUILT FIREMAIN SYSTEM DIAGRAM.pdf","161025 Attachment WW - Powhatan B CAT start air piping (3).JPG","161025 Attachment X - POWHATAN AS-BUILT ENGINE COOLING SYSTEM DIAGRAM.pdf","161025 Attachment XX - POWHATAN OUTBOARD PROFILE LIFE JACKET STORAGE.pdf","161025 Attachment Y - POWHATAN AS-BUILT BILGE AND WASTE OIL SYSTEM.pdf","161025 Attachment Z - POWHATAN AS BUILT COMPRESSED AIR SYSTEM DIAGRAM.pdf","161025 Attachments A-E.pdf","161025 II - Form C-76B - CONTRACTOR’S CERTIFICATE OF COMPLIANCE FOR MANUFACTURED PRODUCTS.pdf","161025 JJ Form C-76 - CONTRACTOR’S CERTIFICATE OF COMPLIANCE FOR STEEL & IRON ITEMS.pdf","IFB 161025 Powhatan Shipyard- Solicitation.pdf"]["600862","3255244","2999320","3532501","3339889","3195351","254788","1701830","1925500","646622","920633","13488175","705506","189616","1762934","1458864","9294329","230735","2399023","73606","793584","32450","759022","1253528","549346","628567","1183303","5119145","259051","235316","259143","4526392","934926","1259122","847287","243749","3750415","765590","7334316","810842","377262","1310226","849131","372769","271333","500427","527672"]"http://www.w3.org/2001/XMLSchema-instance"["7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26","7/31/26"]["IFB 161025 Attachment K - Powhatan Side Shell & Longitudinal Elevation","IFB 161025 Attachment UU - Powhatan B CAT Start Air Piping (1)","IFB 161025 Attachment AA - Powhatan A CAT Start Air Piping (1)","IFB 161025 Attachment BB - Powhatan A CAT Start Air Piping (2)","IFB 161025 Attachment CC - Powhatan A CAT Start Air Piping (3)","IFB 161025 Attachment DD - Powhatan -CO2 Hydro Test Dates","IFB 161025 Attachment EE - MSC.1-Circ.1318-REV. 1","IFB 161025 Attachment F - Federal Aid Construction Contracts FHWA-1273","IFB 161025 Attachment FF - Manchester Air Receiver ID 1 (Picture)","IFB 161025 Attachment G - Specifications for the Maintenance and Repair MV Powhatan","IFB161025 Attachment GG - Manchester Air Receiver ID 2 (Picture)","IFB 161025 Attachment H - 33 CFR 105 Marine Transportation Security Act","IFB161025 Attachment HH - Form C-76A Contractor's Certificate for Construction Materials","IFB 161025 Attachment I - 46CFR Part 1520","IFB 161025 Attachment J - Powhatan Superstructure Scantlings","IFB161025 Attachment KK - Fernstrum Grid Cooler Installation and Maintenance Manual","IFB 161025 Attachment L - Powhatan Red Fox Installation Operation Maintenance Manual","IFB 161025 Attachment LL - CG-ENG PL 02-23 Acceptance of IMO Hydrostatic Guidelines_1","IFB 161025 Attachment M - Powhatan keel cooler layout with notes","IFB 161025 Attachment MM-CFR 147.65 Carbon Dioxide and Halon Fire Extinguishing Systems","IFB 161025 Attachment N - Powhatan General Arrangement","IFB 161025 Attachment NN - 5.07.2.4. Non-Skid Estimated Square Footage Per Space","IFB 161025 Attachment O - Powhatan Fuel Oil System Diagram","IFB 161025 Attachment OO - Voith Health Check Brochure","IFB 161025 Attachment P - Powhatan Fixed Fire Extinguishing System Diagram","IFB 161025 Attachment PP - Voith Expansion Tank Modification","IFB 161025 Attachment Q - Powhatan ER Ventilation Fan (1)","IFB161025 Attachment QQ - Voith Cooling System Leaking Pipe","IFB 161025 Attachment R - Powhatan ER Ventilation Fan (2)","IFB 161025 Attachment RR - VDOT Special Provision SP107-003000-01","IFB 161025 Attachment S - Powhatan Docking Plan & Cathodic Protection","IFB 161025 Attachment SS - VDOT Marine Paint Standards for Preservation","IFB 161025 Attachment T - Powhatan Deck & Bottom Structure","IFB 161025 Attachment TT - Tsurumi Submersible Effluent Pump","IFB 161025 Attachment U - Powhatan AS-Built Seachest","IFB 161025 - Attachment V - Powhatan AS-Built Fresh & Sanitary Water PLMB and DE DRN","IFB 161025 Attachment VV - Powhatan B CAT Start Air Piping (2)","IFB 161025 Attachment W - Powhatan AS-Built Firemain System Diagram","IFB 161025 Attachment WW - Powhatan B CAT Start Air Piping (3)","IFB 161025 Attachment X - Powhatan AS-Built Engine Cooling System Diagram","IFB 161025 Attachment XX - Powhatan Outboard Profile Life Jacket Storage","IFB 161025 Attachment Y - Powhatan AS-Built Bilge and Waste Oil System","IFB 161025 Attachment Z- Powhatan AS Built Compressed Air System Diagram","IFB 161025 Attachments A-E","IFB161025 Attachment II - Form C-76B-Contractor's Certificate of Compliance for Manufactured Products","IFB 161025 Attachment JJ Form C-76-Contractor's Certificate of Compliance for Steel & Iron Items","IFB161025 Powhatan Maintenance and Repair Solicitation"]["RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document","RFx Document"]Source: Virginia eVA (solicitation IV125492), retrieved via Virginia's eVA statewide eProcurement marketplace. View the official posting , always confirm requirements and deadlines with the issuing agency.