- Date Open
- 2026-09-23 19:00:00
- Best Value
- 0
- Budget Low
- 0.00
- Date Close
- 2026-10-29 19:00:00
- Is Created
- 1
- Is Deleted
- 0
- Project ID
- 255427
- Budget High
- 0.00
- Date Created
- 2026-09-22 21:01:33
- Has Auctions
- 0
- Is Protected
- 0
- Is Simple Bid
- 0
- Project Name
- PW - 103497-2 Marine Creek Sanitary Sewer Parallel Interceptor M-279 & M-245B - Part II
- Project Type
- ITB
- Public QAnd A
- 0
- Reference ID
- 26-0332
- Date Modified
- 2026-09-24 19:24:49
- Department ID
- 9147
- Has Bid Tables
- 1
- Rank Analysis
- 0
- Creator User ID
- 884458
- Date Evaluated
- 2026-12-18 20:00:00
- Flexible Layout
- 0
- Organization ID
- 821
- Project Sub Type
- 1
- Submission Type
- 1
- Has Been Released
- 0
- Has Pricing Sheet
- 0
- Informal Project
- 0
- Project Status ID
- 2
- Statement Of Work
- Unit I: Sanitary Sewer Improvements
1. Installation of approximately 3,960 LF of 48-inch thru 72-inch sanitary sewer pipe by open cut with all associated appurtenances and required testing.
2. Installation of approximately 570 LF of 72-inch sanitary sewer pipe with 90-inch steel casing pipe by other than open cut (Open-Shield Pipejacking) with all associated appurtenances and required testing.
3. Installation of approximately 2,430 LF of 48-inch thru 72-inch sanitary sewer pipe by other than open cut within 60-inch thru 90-icnh steel casing pipe or 60-inch thru 100-inch tunnel liner plate with all associated appurtenances and required testing.
4. Installation of approximately 1,470 LF of 6-inch thru 18-inch sanitary sewer pipe by open cut with all associated appurtenances and required testing.
5. Bypass Pumping of existing sanitary sewer lines.
6. Construction of (2) sanitary sewer siphon structures
7. Construction of (2) sanitary sewer junction structures
Unit II: Water Improvements
1. Installation of approximately 2,200 LF of 36-inch water pipe by open cut with all associated appurtenances and required testing.
2. Installation of approximately 280 LF of 36-inch water pipe with 48-inch steel casing pipe or 50-inch tunnel liner plate by other than open cut with all associated appurtenances and required testing.
3. Installation of approximately 425 LF of 24-inch AWWA C200 Steel water pipe on existing bridge with all associated appurtenances and required testing.
4. Installation of approximately 4,330 LF of 6-inch thru 12-inch water pipe by open cut with all associated appurtenances and required testing.
5. Cathodic Protection of 24-inch thru 36-inch water pipe with all associated appurtenances and required testing.
- Consensus Scoring
- 0
- Date Questions Due
- 2026-10-23 19:00:00
- Private Project ID
- 702b416455188d52695b9e3e90256759
- Has Questionnaires
- 1
- Accepts Submissions
- 1
- Advanced Algorithms
- 0
- Date Intent To Bid Due
- 2026-10-29 19:00:00
- Project Sub Status ID
- 1
- Max Alternate Options
- 0
- Project Visibility ID
- 1
- Run Validation Checks
- 0
- Anonymous Submissions
- 0
- Public Document Takers
- 0
- Subcontractor Listing
- 1
- Contact Info Visibility
- 3
- Multi Category Decisions
- 0
- Opportunity Intent To Bid
- 1
- Pending Questions Public
- 0
- Project Proposal Analysis
- 1
- Decision Sensitivity Analysis
- 0
- Question Set Scoring Algorithm Version
- 2
- Is Project Post Evaluation Documents Hidden
- 0